Knowledge
Sources and scope
Research, information from public authorities, supplier information and our own calculations are presented separately. The review level indicates whether the full text or only the abstract has been read.
- Project
Leak detection in vacuum systems – insights from the Oceanhamnen demo
Interreg North Sea, ANCHOR
Supports: Continuous pressure monitoring and monthly leak tests; larger leaks can increase energy use and disrupt operation.
Scope: Article dated 3 April 2026. Shows operational tasks, not the number of vacancies.
Reviewed: Full text · Checked 2026-10-12
Supports: Four demonstration sites, four operating manuals and three video demonstrations for vacuum systems.
Scope: Background information. Rights are checked before reuse. No partnership.
Reviewed: Summary · Checked 2026-10-12
Supports: 1,160.7 m³ of flushing water saved per year (88.3%); SEK 69,642 gross at an assumed SEK 60/m³.
Scope: 100 users × 6 flushes per person per day × 365 days, 6 l versus 0.7 l. Applies to flushing water, not the entire building. No measured effect of training.
Reviewed: Own calculation · Checked 2026-11-13
- Research
Slutrapport EHLSA – Ett vattenhållbar lokal systemomställning för global applikation
Water Wise Societies / EHLSA
Supports: A lack of expertise in alternative systems makes procurement, installation, operation and maintenance more difficult.
Scope: PDF pp. 16–18, 25, 38–39. Supports the proposed direction; no approval of Vakuumsäker’s courses.
Reviewed: Full text · Checked 2026-10-12
Supports: 207 hotel rooms below sewer level in a former parking garage in London.
Scope: The supplier’s project description. Not a Vakuumsäker reference project. The savings are a forecast.
Reviewed: Full text · Checked 2026-10-12
Supports: Specialist expertise is needed from planning through operation; air leakage and valve performance affect operating costs.
Scope: December 2016.
Reviewed: Full text · Checked 2026-10-12
- Public authority
Utvärdering av användaraspekter av vakuumtoaletter till sluten tank
Havs- och vattenmyndigheten
Supports: A need for clear installation and adjustment instructions, user information and effective service arrangements.
Scope: Report summary. 80% of respondents satisfied; response rate unknown — not generalised.
Reviewed: Summary · Checked 2026-10-12
Supports: Approximately 700,000 small wastewater systems serving flush toilets in Sweden.
Scope: Last updated in 2020 — older authority information, not a new survey.
Reviewed: Full text · Checked 2026-10-12
- Research
Comparative evaluation of vacuum sewer and gravity sewer systems
Islam, Int J Syst Assur Eng Manag 8:37–53
Supports: Approximately 30% lower total costs and 75% lower excavation costs for vacuum networks in the areas studied.
Scope: Only the publisher’s abstract reviewed. Designed networks, not measured Swedish operation.
Reviewed: Abstract · Checked 2026-10-12
Supports: Arbetsförmedlingen’s five-year assessment indicates strong employment opportunities for occupational groups including heating, ventilation and plumbing engineers/technicians and installers.
Scope: PDF pp. 11, 15–16. 81 ± 7% concerns heating, ventilation and plumbing designers graduating from full higher vocational education programmes in 2023 — not outcomes of Vakuumsäker’s short courses.
Reviewed: Full text · Checked 2026-10-12
Supports: Continuing skills shortages and substantial needs associated with maintenance and new construction in water and wastewater services.
Scope: Report year 2024, PDF p. 17. Water and wastewater generally, not specific demand for vacuum expertise.
Reviewed: Full text · Checked 2026-10-12
Supports: Urine scale in vacuum pipes in Oceanhamnen; a project is developing maintenance recommendations.
Scope: Camera inspections in 2024; maintenance recommendations planned for spring 2027.
Reviewed: Full text · Checked 2026-10-12
Supports: The authorities seek analyses of socioeconomic, legal and social conditions for source separation and improved water efficiency.
Scope: The call closed on 14 September 2026. Must not be shown as open funding.
Reviewed: Full text · Checked 2026-10-12
Supports: A developed vacuum toilet using 0.5–0.7 litres per flush.
Scope: Applies to a developed ultra-low-water-use model, not all products.
Reviewed: Full text · Checked 2026-10-12
Supports: Tax liability and VAT depend on the nature of activities and income.
Scope: Association status does not automatically mean tax exemption or VAT-exempt sales.
Reviewed: Full text · Checked 2026-10-12
Supports: Water and wastewater are described as core technical systems within the programme.
Scope: Programme description. The school package is not approved by Skolverket and is not a standalone upper secondary course.
Reviewed: Summary · Checked 2026-10-12
- Industry report
Investeringsbehov och framtida kostnader för kommunalt vatten och avlopp, R2023-02
Svenskt Vatten
Supports: Investment needs are estimated at SEK 560 billion up to 2040, approximately SEK 31 billion per year.
Scope: The entire municipal water and wastewater sector, report estimate from 2023, PDF p. 8. Not an order volume for vacuum technology or Vakuumsäker.
Reviewed: Full text · Checked 2026-10-12
Supports: Fully source-separating system: approximately 20% higher life-cycle cost in the comparison.
Scope: Scenario over 50 years. Older monetary input data.
Reviewed: Full text · Checked 2026-10-12
Supports: Accredited certification of persons follows ISO/IEC 17024 and Swedac’s procedure.
Scope: Reference for a possible future development pathway. Vakuumsäker is not accredited.
Reviewed: Full text · Checked 2026-10-12
Supports: Label requirements in procurement are subject to specific rules; equivalent evidence must be accepted.
Scope: Guidance on labels in public procurement.
Reviewed: Full text · Checked 2026-10-12